{ "schema_version": "1.4.0", "id": "GHSA-x5rg-6gf6-5wg5", "modified": "2024-04-04T06:44:23Z", "published": "2023-08-09T12:30:26Z", "aliases": [ "CVE-2023-32782" ], "details": "An issue was discovered in Paessler PRTG Network Monitor 23.2.83.1760. Due to command-line parameter injection and an undocumented debug feature flag, an attacker can utilize the DICOM sensor to write arbitrary data to the disk. This can be utilized to write a custom EXE(.bat) sensor, that will then run. This primitive gives remote code execution.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-32782" }, { "type": "WEB", "url": "https://kb.paessler.com/en/topic/91845-multiple-vulnerabilites-fixed-in-paessler-prtg-network-monitor-23-3-86-1520" }, { "type": "WEB", "url": "https://www.paessler.com/prtg/history/stable" } ], "database_specific": { "cwe_ids": [ "CWE-77" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-08-09T12:15:10Z" } }