{ "schema_version": "1.4.0", "id": "GHSA-49g6-wr7w-v4jj", "modified": "2024-05-16T18:30:32Z", "published": "2024-05-16T18:30:32Z", "aliases": [ "CVE-2024-3640" ], "details": "An unquoted executable path exists in the Rockwell Automation FactoryTalk® Remote Access™ possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a System user. A threat actor needs admin privileges to exploit this vulnerability.", "severity": [], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-3640" }, { "type": "WEB", "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1671.html" } ], "database_specific": { "cwe_ids": [ "CWE-428" ], "severity": null, "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-05-16T16:15:10Z" } }