e used to calculate the vsel values to be programmed in the VREG_VOLTAGE registers. Voltage(in mV) = 1000mv + 100mv * (vsel - 1) Ex: if vsel = 0x9, mV = 1000 + 100 * (9 -1) = 1800mV. This patch removes all existing VSEL tables for twl6030 adjustable regulators and just uses the formula directly for vsel calculations after verifing they fall in the allowed range. Signed-off-by: Rajendra Nayak Cc: Liam Girdwood Cc: Samuel Ortiz Cc: Mark Brown Acked-by: Mark Brown Signed-off-by: Liam Girdwood