{ "schema_version": "1.4.0", "id": "GHSA-264m-mv26-f7f5", "modified": "2022-05-13T01:34:23Z", "published": "2022-05-13T01:34:23Z", "aliases": [ "CVE-2018-14829" ], "details": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-14829" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "type": "WEB", "url": "https://www.tenable.com/security/research/tra-2018-26" } ], "database_specific": { "cwe_ids": [ "CWE-119" ], "severity": "CRITICAL", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-09-20T19:29:00Z" } }