{ "schema_version": "1.4.0", "id": "GHSA-27cv-whxj-627j", "modified": "2022-05-13T01:50:59Z", "published": "2022-05-13T01:50:59Z", "aliases": [ "CVE-2018-20218" ], "details": "An issue was discovered on Teracue ENC-400 devices with firmware 2.56 and below. The login form passes user input directly to a shell command without any kind of escaping or validation in /usr/share/www/check.lp file. An attacker is able to perform command injection using the \"password\" parameter in the login form.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-20218" }, { "type": "WEB", "url": "https://zxsecurity.co.nz/research.html" }, { "type": "WEB", "url": "http://seclists.org/fulldisclosure/2019/Feb/48" } ], "database_specific": { "cwe_ids": [ "CWE-78" ], "severity": "CRITICAL", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-03-21T16:00:00Z" } }