{ "schema_version": "1.4.0", "id": "GHSA-6xw6-4hxh-3v2w", "modified": "2022-05-24T17:48:18Z", "published": "2022-05-24T17:48:18Z", "aliases": [ "CVE-2020-27736" ], "details": "A vulnerability has been identified in Nucleus 4 (All versions < V4.1.0), Nucleus NET (All versions), Nucleus RTOS (versions including affected DNS modules), Nucleus ReadyStart (All versions < V2017.02.3), Nucleus Source Code (versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), VSTAR (versions including affected DNS modules). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-27736" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-125", "CWE-170", "CWE-193" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-04-22T21:15:00Z" } }