{ "schema_version": "1.4.0", "id": "GHSA-625f-424x-6j4w", "modified": "2022-05-24T17:27:38Z", "published": "2022-05-24T17:27:38Z", "aliases": [ "CVE-2020-15787" ], "details": "A vulnerability has been identified in SIMATIC HMI United Comfort Panels (All versions). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.", "severity": [], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-15787" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542525.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-287", "CWE-305" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-09-09T19:15:00Z" } }