{ "schema_version": "1.4.0", "id": "GHSA-c2jm-2fx3-h7g6", "modified": "2022-05-13T01:35:49Z", "published": "2022-05-13T01:35:49Z", "aliases": [ "CVE-2018-0102" ], "details": "A vulnerability in the Pong tool of Cisco NX-OS Software could allow an unauthenticated, adjacent attacker to cause a reload of an affected device, resulting in a denial of service (DoS) condition. The vulnerability exists because the affected software attempts to free the same area of memory twice. An attacker could exploit this vulnerability by sending a pong request to an affected device from a location on the network that causes the pong reply packet to egress both a FabricPath port and a non-FabricPath port. An exploit could allow the attacker to cause a dual or quad supervisor virtual port-channel (vPC) to reload. This vulnerability affects the following products when running Cisco NX-OS Software Release 7.2(1)D(1), 7.2(2)D1(1), or 7.2(2)D1(2) with both the Pong and FabricPath features enabled and the FabricPath port is actively monitored via a SPAN session: Cisco Nexus 7000 Series Switches and Cisco Nexus 7700 Series Switches. Cisco Bug IDs: CSCuv98660.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-0102" }, { "type": "WEB", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-nx-os" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/102728" }, { "type": "WEB", "url": "http://www.securitytracker.com/id/1040219" } ], "database_specific": { "cwe_ids": [ "CWE-415" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-01-18T06:29:00Z" } }