{ "schema_version": "1.4.0", "id": "GHSA-cgc9-524g-5jwr", "modified": "2022-05-12T00:01:46Z", "published": "2022-05-12T00:01:46Z", "aliases": [ "CVE-2021-34606" ], "details": "A vulnerability exists in XINJE XD/E Series PLC Program Tool in versions up to v3.5.1 that can allow an authenticated, local attacker to load a malicious DLL. Local access is required to successfully exploit this vulnerability. This means the potential attacker must have access to the system and sufficient file-write privileges. If exploited, the attacker could place a malicious DLL file on the system, that when running XINJE XD/E Series PLC Program Tool will allow the attacker to execute arbitrary code with the privileges of another user's account.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-34606" }, { "type": "WEB", "url": "https://claroty.com/2022/05/11/blog-research-from-project-file-to-code-execution-exploiting-vulnerabilities-in-xinje-plc-program-tool" } ], "database_specific": { "cwe_ids": [ "CWE-427" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-05-11T15:15:00Z" } }