{ "schema_version": "1.4.0", "id": "GHSA-cjj8-hc6q-2699", "modified": "2022-05-14T03:44:30Z", "published": "2022-05-14T03:44:30Z", "aliases": [ "CVE-2018-5761" ], "details": "A man-in-the-middle vulnerability related to vCenter access was found in Rubrik CDM 3.x and 4.x before 4.0.4-p2. This vulnerability might expose Rubrik user credentials configured to access vCenter as Rubrik clusters did not verify TLS certificates presented by vCenter.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-5761" }, { "type": "WEB", "url": "https://gist.github.com/srau/0ed7747953b3571247a6c485f91619ff" }, { "type": "WEB", "url": "https://support.rubrik.com/articles/How_To/000001135" } ], "database_specific": { "cwe_ids": [ "CWE-295" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-01-22T17:29:00Z" } }