{ "schema_version": "1.4.0", "id": "GHSA-cxf9-4ff5-hx4j", "modified": "2022-05-24T19:14:02Z", "published": "2022-05-24T19:14:02Z", "aliases": [ "CVE-2021-40222" ], "details": "Rittal CMC PU III Web management Version affected: V3.11.00_2. Version fixed: V3.17.10 is affected by a remote code execution vulnerablity. It is possible to introduce shell code to create a reverse shell in the PU-Hostname field of the TCP/IP Configuration dialog. Web application fails to sanitize user input on Network TCP/IP configuration page. This allows the attacker to inject commands as root on the device which will be executed once the data is received.", "severity": [], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-40222" }, { "type": "WEB", "url": "https://github.com/asang17/CVE-2021-RCE" } ], "database_specific": { "cwe_ids": [ "CWE-78" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-09-09T12:15:00Z" } }