{ "schema_version": "1.4.0", "id": "GHSA-g28c-477m-v5p9", "modified": "2024-01-09T12:30:34Z", "published": "2022-05-24T17:03:29Z", "aliases": [ "CVE-2019-18341" ], "details": "A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The SFTP service (default port 22/tcp) of the SiNVR 3 Central Control Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-18341" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-287" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-12-12T19:15:00Z" } }