{ "schema_version": "1.4.0", "id": "GHSA-g2fr-hgr5-r3hq", "modified": "2022-07-02T00:00:21Z", "published": "2022-05-24T17:38:29Z", "aliases": [ "CVE-2020-15800" ], "details": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-15800" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-122", "CWE-787" ], "severity": "CRITICAL", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-01-12T21:15:00Z" } }