{ "schema_version": "1.4.0", "id": "GHSA-jrcf-p229-q8r2", "modified": "2022-05-14T01:45:26Z", "published": "2022-05-14T01:45:26Z", "aliases": [ "CVE-2018-16713" ], "details": "IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2018-16713" }, { "type": "WEB", "url": "https://downwithup.github.io/CVEPosts.html" } ], "database_specific": { "cwe_ids": [ "CWE-119" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-09-26T22:29:00Z" } }