{ "schema_version": "1.4.0", "id": "GHSA-rfr4-xxfq-6j5j", "modified": "2022-05-13T01:36:36Z", "published": "2022-05-13T01:36:36Z", "aliases": [ "CVE-2017-6015" ], "details": "Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2017-6015" }, { "type": "WEB", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02" }, { "type": "WEB", "url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/96996" } ], "database_specific": { "cwe_ids": [ "CWE-74" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2018-05-11T13:29:00Z" } }