{ "schema_version": "1.4.0", "id": "GHSA-w5f6-9h7r-9v63", "modified": "2025-04-20T03:45:53Z", "published": "2022-05-17T00:47:38Z", "aliases": [ "CVE-2017-9956" ], "details": "An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2017-9956" }, { "type": "WEB", "url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01" }, { "type": "WEB", "url": "http://www.securityfocus.com/bid/99344" } ], "database_specific": { "cwe_ids": [ "CWE-798" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2017-09-26T01:29:00Z" } }