{ "schema_version": "1.4.0", "id": "GHSA-wv2p-5j7g-h596", "modified": "2022-05-24T17:10:37Z", "published": "2022-05-24T17:10:37Z", "aliases": [ "CVE-2019-19298" ], "details": "A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The streaming service (default port 5410/tcp) of the SiNVR 3 Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requeats.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-19298" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-20" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-03-10T20:15:00Z" } }