{ "schema_version": "1.4.0", "id": "GHSA-j3gr-58v5-64m3", "modified": "2022-09-13T00:00:40Z", "published": "2022-09-07T00:01:49Z", "aliases": [ "CVE-2022-1522" ], "details": "The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-117: Improper Output Neutralization for Logs, which allows an attacker to create false logs that show the password as having been changed when it is not, complicating forensics.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-1522" }, { "type": "WEB", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-03" } ], "database_specific": { "cwe_ids": [ "CWE-117" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-09-06T23:15:00Z" } }