{ "schema_version": "1.4.0", "id": "GHSA-9fhw-hf7x-9gjc", "modified": "2025-04-23T18:30:40Z", "published": "2022-12-09T00:30:18Z", "aliases": [ "CVE-2022-38765" ], "details": "Canon Medical Informatics Vitrea Vision 7.7.76.1 does not adequately enforce access controls. An authenticated user is able to gain unauthorized access to imaging records by tampering with the vitrea-view/studies/search patientId parameter.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-38765" }, { "type": "WEB", "url": "https://www.vitalimages.com/customer-success-support-program/vital-images-software-security-updates" } ], "database_specific": { "cwe_ids": [ "CWE-639" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-12-09T00:15:00Z" } }