{ "schema_version": "1.4.0", "id": "GHSA-c28m-8g89-fpm5", "modified": "2022-12-07T15:30:29Z", "published": "2022-12-01T18:30:47Z", "aliases": [ "CVE-2022-2969" ], "details": "Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-2969" }, { "type": "WEB", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-307-03" } ], "database_specific": { "cwe_ids": [ "CWE-22" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-12-01T18:15:00Z" } }