{ "schema_version": "1.4.0", "id": "GHSA-q9cw-p99m-h9cm", "modified": "2023-01-14T03:30:22Z", "published": "2023-01-10T12:30:23Z", "aliases": [ "CVE-2022-45094" ], "details": "A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially inject commands into the dhcpd configuration of the affected product. An attacker might leverage this to trigger remote code execution on the affected component.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-45094" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf" } ], "database_specific": { "cwe_ids": [ "CWE-77" ], "severity": "HIGH", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-01-10T12:15:00Z" } }