{ "schema_version": "1.4.0", "id": "GHSA-j998-c4rh-83vq", "modified": "2023-02-23T06:30:17Z", "published": "2023-02-13T12:30:25Z", "aliases": [ "CVE-2023-0808" ], "details": "A vulnerability was found in Deye/Revolt/Bosswerk Inverter MW3_15U_5406_1.47/MW3_15U_5406_1.471. It has been rated as problematic. This issue affects some unknown processing of the component Access Point Setting Handler. The manipulation with the input 12345678 leads to use of hard-coded password. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. Upgrading to version MW3_16U_5406_1.53 is able to address this issue. It is recommended to upgrade the affected component. The identifier VDB-220769 was assigned to this vulnerability.", "severity": [ { "type": "CVSS_V3", "score": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "affected": [], "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-0808" }, { "type": "WEB", "url": "https://heise.de/-7483376" }, { "type": "WEB", "url": "https://vuldb.com/?ctiid.220769" }, { "type": "WEB", "url": "https://vuldb.com/?id.220769" } ], "database_specific": { "cwe_ids": [ "CWE-259", "CWE-798" ], "severity": "MODERATE", "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-02-13T12:15:00Z" } }